跳至主要内容

Solved: iPhone 6 Plus with Abnormal Current

We are going to fix the iPhone 6 plus with some faults, first problem it that we can't turn it on and the constant current is shown as 70mA. It was repaired before as its unresponsive touch.

When soldering touch chip, the front camera socket dropped because the air gun had higher temperature. After soldering front Camera FPC Connector socket, I found that the front camera still could not be used. I blew the area near fingerprint socket. It cannot be turn on completely.
Customer only sent the motherboard, so I energize it and test. The constant current is 70mA and it stops.
Based on my experience, constant current stops at 70mA mainly because of the bus. I go on to measure the diode data of bus voltage. The data is normal. Many reasons can lead to turn on failure. If we want to narrow the problem scope, we can use root method. The customer agrees me to root. It reports unknown error (4005). Based on my experience, I know that CPU or temporary storage, as shown in the picture.



The major point of soldering CPU lies in the treatment to the top of the CPU lower board, as shown in the picture.



After soldering the CPU lower board, assemble the iPhone and test. The current is normal. I continue to assemble the temporary storage, finding that the current still stops at 70mA, which is abnormal. Obviously the problem lies in temporary storage, as shown in the following picture. Then I turn it on to test. All the functions are normal. Trouble is removed.



That's the complete process for the iPhone 6 plus repair, more cell phone maintenance skills check at www.vipfixphone.com

评论

此博客中的热门博文

Solution: Why iPhone X Voltage Keeps Jumping

After getting the iPhone X motherboard to test, we observe the current value repeatedly jumps between 0mA and 50mA on DC power supply , and it is different from the normal booting current. Next, test whether the power supply of every circuit is normal. PP_VDD_MAIN is measured 4.2V; PP_VDD_BOOST measured is 4.2V. PP1V8-ALWAYS is 1.8V, all the values are normal. But when testing PP1V1_S2, PP0V8_SOC_FIXED_S1, PP1V8_S2 and other circuit voltage that output by power chip U2700 voltage are jumping constantly. According to previous experience, voltage jump is usually caused by a power supply circuit of U2700 output. Measured with digital multimeter , there is no short circuit was found for the dipole value of all power supply to ground. We repaired iPhone 7P before and know that if crystal oscillator is false welding can also cause voltage jumping, And if iPhone CPU  power supply is abnormal also can cause voltage jumping. Check the crystal oscillator we find no problem, then check th...

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Iphone 6S Enters DFU Mode Cannot Start Fault Repair

The customer said that he did not know what the reason was. The mobile phone has been restarted indefinitely and can enter the DFU mode. However, when the flashing machine fails to enter the recovery mode from the DFU mode, and then the mobile phone is connected to the computer for 5-10 minutes, it automatically enters the recovery mode. After we received the 6S that could not be started, we disassembled the power with iphone engraving tool and turned on the power to 100mA. First of all, check if you can connect and read the DFU mode after connecting to the computer. Wireless DFU can not exit, we can only brush the machine to view the error. Refresh Aisi and iTunes respectively. If you stuck on the progress bar for a long time, it is very likely that the error is -1. If the progress bar does not enter, you can roughly determine the probability of a CPU failure. Now we need to see if there is a problem with the hard drive. First, use DC power supply for iphone repair, the hard disk o...