跳至主要内容

Solution: iPhone 6 Booting with200mA Electric Leakage

According to our phone fix experience, if a cell phone device is tested as 200mA electric leakage when booting, we generally choose to replace USB tube. However, this is not absolute, the iPhone 6 we received is not caused by USB tube fault.


Connecting the iPhone 6 with multimeter, the current shows 200mA. we directly replace a USB tube. The result is that the current is still in the 200mA position after waiting for a few minutes.

So we wonder if there is another fault symptom happened, the last repair technician mentioned the iPhone 6 fingerprint is not good.

When heard of this problem, we can basically judge where the problem is. Connecting multimeter and trigger the switch current with 300-400 mA, this is not normal. There must be something wrong with the fingerprint 3V. Use the multimeter to test fingerprint 3V against the ground value, it is short. This kind of situation is generally caused by one of outside capacitance is short, dismantling it! Finally, we find out the C2133 is short circuit, pry it off, reboot the iPhone 6 and retest the standby value is normal, and the fingerprint is also normal now.

The iPhone 6 schematic diagram IC postion is shown in picture 11-8-1.

Summary of leakage detection process:

We must test the function of system as possible we can in advance if we encounter the leakage, which will be repaired if any of the functions are tested abnormal, if all is normal, USB tube will be required to pay more attention. USB tube is also a problem, if it gets bad, the function will be normal and no problem can not be detected. If there is a electric leakage on the iPhone, you can first press the iPhone power button and loose to see how much the current will be. In the normal case, it is about one hundred. If it jumps to three hundred or four hundred, there must be electric leakage, and jump to two hundred or three hundred leakage is basically caused by several 3V: The 3v power supply of USB tube, the 3V of fingerprint and the 3V of compass.

If you need more mobile phone fix knowledge, please visit at www.vipfixphone.com

评论

此博客中的热门博文

Solution: iPhone X Won't Turn On

According to the customer's description, the iPhone X would not turn on after it drop accidentally. Then the cell phone reports error 56 when restore it. How did this happen? Let's test and repair step by step. Since iPhone X motherboard 2 layers are connected through the middle column, the solder points are very easy to get dropped. so we guess that the solder points from NFC chip to the CPU part have fell off. Disassemble the iPhone X by iPhone opening tools , remove the upper board off the main board, when separate the main board we see there is a row of points have fell off. Check the location map on WUXINJI dongle , it is surrounded by a ground wire, in fact, there are 6 useful points dropped. The ground wire does not need to be filled, the 6 useful points are added by professional phone welding tools. These are the signal wires of the NFC chip, so the iPhone X would report error 56. Then the tin of the middle column is repaired by iPhone X BGA reballing ste...

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Solution: Why iPhone X Voltage Keeps Jumping

After getting the iPhone X motherboard to test, we observe the current value repeatedly jumps between 0mA and 50mA on DC power supply , and it is different from the normal booting current. Next, test whether the power supply of every circuit is normal. PP_VDD_MAIN is measured 4.2V; PP_VDD_BOOST measured is 4.2V. PP1V8-ALWAYS is 1.8V, all the values are normal. But when testing PP1V1_S2, PP0V8_SOC_FIXED_S1, PP1V8_S2 and other circuit voltage that output by power chip U2700 voltage are jumping constantly. According to previous experience, voltage jump is usually caused by a power supply circuit of U2700 output. Measured with digital multimeter , there is no short circuit was found for the dipole value of all power supply to ground. We repaired iPhone 7P before and know that if crystal oscillator is false welding can also cause voltage jumping, And if iPhone CPU  power supply is abnormal also can cause voltage jumping. Check the crystal oscillator we find no problem, then check th...