Charging failure is a
common problem in cell phone repairs, here we are going to talk about how to test and repair iPhone 6S Plus charging failure. iPhone 6S Plus charging failure, including the iPhone battery power percentage is getting less during
the charging, power down status can be charged successfully but cannot charge
after boot and unable to recognize USB, etc.
Check iPhone schematic diagram on WUXINJI Dongle, we found that the PP5V0_USB(5.0V) that
was sent from the iPhone Tail Plug circuit, and then continue sent to the
charging IC via the trailing plug interface, and then go through the charging
protect tube, finally send it to iPhone USB control IC.
After disassemble the iPhone by phone opening
tools, remove the iPhone motherboard, use Fluke 15B+Digital Multimeter to measure the 5.0V voltage (PP5V0_USB)
next to the charging IC, and then measure the 5.0V voltage (PP5V0_USB) next to
the USB control IC to check is it working properly.
If both these 5.0V is working properly,
then you just need replace the iPhone charging IC and
USB control IC.
If 5.0V(PP5V0_USB) next to charging IC
exist, but 5.0V(PP5V0_USB) next to USB control IC doesn't exist, the iPhone
power down status can be charged successfully but cannot charge after boot, or
can't recognize USB. In order to fix this trouble, we can use hot air gun to short connect charge protection tube.
Moreover, damaged charging capacitor L2300
also will cause iPhone power percentage won't increase during the charging.
If you want to get any cell phone repair skills or tutorials, please click www.vipfixphone.com