Received a iPhone 6 from one of our customers, according to his description, the device was working well and no any dropping or other damages. When he uses it like before, the iPhone screen suddenly doesn't display anything. What is the problem? Let's read in article.

1. Check iPhone 6 schematic diagram on WUXINJI Dongle, and then we know the iPhone 6 display socket circuit diagram.
 


2. Use Fluke15B+ Digital Multimeter to measure the diode data of iPhone display touch socket, finding the 26 pin circuit is shorted; The display screen is positive 5.7V.

3. By reading iPhone schematic diagram, we know that this circuit is output by iPhone displaytouch IC, there are 6 filter capacitors on this circuit line.

4. Based on previous repair experience, we judged that the filter capacitors are damaged. Put iPhone motherboard under the Phone Repair 7-45X Trinocular Stereo Microscope, and then remove the filter capacitors one by one, when breaking into the third filter capacitor, the data measured is normal.
 


5. Install the iPhone, and then press iPhone power button to turn it on, the Apple logo appears on iPhone display screen smoothly. After get into IOS, the iPhone screen is always displaying normally.

More cell phone repair skills and related tools read on www.vipfixphone.com

评论

此博客中的热门博文

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Solution: Why iPhone X Voltage Keeps Jumping

After getting the iPhone X motherboard to test, we observe the current value repeatedly jumps between 0mA and 50mA on DC power supply , and it is different from the normal booting current. Next, test whether the power supply of every circuit is normal. PP_VDD_MAIN is measured 4.2V; PP_VDD_BOOST measured is 4.2V. PP1V8-ALWAYS is 1.8V, all the values are normal. But when testing PP1V1_S2, PP0V8_SOC_FIXED_S1, PP1V8_S2 and other circuit voltage that output by power chip U2700 voltage are jumping constantly. According to previous experience, voltage jump is usually caused by a power supply circuit of U2700 output. Measured with digital multimeter , there is no short circuit was found for the dipole value of all power supply to ground. We repaired iPhone 7P before and know that if crystal oscillator is false welding can also cause voltage jumping, And if iPhone CPU  power supply is abnormal also can cause voltage jumping. Check the crystal oscillator we find no problem, then check th...

Solution: iPhone 6 Signal Has No Service

We are going to fix an iPhone 6 device today, the iPhone 6 signal keeps searching state after booting, there is no baseband in local setting, and no series number shows up when dialing *#06# serial number. We find the iPhone 6 LCD (has been replaced once, this kind of situation is preliminary determined for baseband CPU false welding, it is relatively common situation on iPhone 6 and iPhone 6P. Anyway we need to test first! From the simple start, measuring the single iPhone 6 motherboard  baseband power supply, first measure the main power supply 4.2V (C3221_RF). Then testing basebnd output voltage of power supply on C3262, C3252, C3259, C3256, if there is a voltage without first measuring resistance, if resistance is normal, then replace normal baseband power test; if four of them are simultaneously without resistance, then you need to reinstall the baseband CPU. There is a small glass tube base strip above the baseband power supply, it must be noticed when the main ...