跳至主要内容

The Best Solution for iPhone 6 Charging Failure

Have you ever met the same situation on your iPhone 6? iPhone 6 charging failure is very common for cell phone repair professionals. However, there are many different reasons may cause this failure. In this article, we are going to fix the fault step by step, let's have a look how to solve it:


1. After taking off iPhone 6 screen, directly test the battery seat voltage B+ with
 Fluke 15B+ Digital Multimeter, it is 0.46 V, there is no voltage can directly exclude the battery problem.

2. Test battery seat resistance B+385 (abnormal resistance will cause white apple restart symptom) normal, disassemble the single board test the 5V sent by USB. There is a test point below the battery interface. If there is 5V, it means there is no problem with the tail plug flex cable(if not, then replace a new tail plug flex cable to test again).

Now we are continue to test the IC with failure


3. Use multimeter to measure whether the capacitance C1704, C1408 has 5V voltage, if neither of them has 5V voltage, you can short connect Q1701' s pin 1 and pin 3. If either of the two capacitance has 5V voltage, then
 jumper wire can help to solve. At the same time, Q1701 may cause the phenomenon: turn off the iPhone 6 can be charged while boot can not be charged. the same method short connection can be applied for solving this problem.
4. 
If both 5V power supply are normal, then test the 4.2V on the battery seat and test the C1417 and C1412. If either of them has no 4.2V, you can short connect Q1403; If both of them have no normal voltage, then you can replace the U2 (U1700) or the U1401 charge tube. U1401 charging tube damage usually has charging icon, and the more electric charge is, the less charge will increase, it won't increase anymore when approaching the certain electric charge.


5. U2 is easy to get damaged in iPhone repair(single board boot 250mA, with DC power supply, it will auto jump about 200mA, battery power display is inaccurate, battery power consumption fast, unable to identify USB, non computer and so on).
8. The NAND is on the top of U2, and there is baseband power below U2. There is a baseband CPU on the back of it. Before disassembly, you can use heat resistant tape to protect the ICs from high temperature and cause other problems. Charging fault detection method for iPhone is basically universal (U2 chip A3B model is common used for iPhone 7).

If you want to get more iPhone repair tutorials and related repair tools, please visit 
www.vipfixphone.com

评论

此博客中的热门博文

Solution: iPhone X Won't Turn On

According to the customer's description, the iPhone X would not turn on after it drop accidentally. Then the cell phone reports error 56 when restore it. How did this happen? Let's test and repair step by step. Since iPhone X motherboard 2 layers are connected through the middle column, the solder points are very easy to get dropped. so we guess that the solder points from NFC chip to the CPU part have fell off. Disassemble the iPhone X by iPhone opening tools , remove the upper board off the main board, when separate the main board we see there is a row of points have fell off. Check the location map on WUXINJI dongle , it is surrounded by a ground wire, in fact, there are 6 useful points dropped. The ground wire does not need to be filled, the 6 useful points are added by professional phone welding tools. These are the signal wires of the NFC chip, so the iPhone X would report error 56. Then the tin of the middle column is repaired by iPhone X BGA reballing ste...

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Solution: Why iPhone X Voltage Keeps Jumping

After getting the iPhone X motherboard to test, we observe the current value repeatedly jumps between 0mA and 50mA on DC power supply , and it is different from the normal booting current. Next, test whether the power supply of every circuit is normal. PP_VDD_MAIN is measured 4.2V; PP_VDD_BOOST measured is 4.2V. PP1V8-ALWAYS is 1.8V, all the values are normal. But when testing PP1V1_S2, PP0V8_SOC_FIXED_S1, PP1V8_S2 and other circuit voltage that output by power chip U2700 voltage are jumping constantly. According to previous experience, voltage jump is usually caused by a power supply circuit of U2700 output. Measured with digital multimeter , there is no short circuit was found for the dipole value of all power supply to ground. We repaired iPhone 7P before and know that if crystal oscillator is false welding can also cause voltage jumping, And if iPhone CPU  power supply is abnormal also can cause voltage jumping. Check the crystal oscillator we find no problem, then check th...