This iPhone 6 device has been repaired before, the main fault is the charging problem, although the screen shows a charge icon, but the power does not really enter the mobile phone, and the phone reboots sometimes. After receiving this fault cell phone, we found that the main board charging chip, battery and accessories were replaced before.



1. Measure the voltage of (C1408, C1700) USB were given to U1401 charge tube and U1700 (U2), the both 5V value are normal.

2. Remove the U2 and charge tube respectively, measure the bottom voltage to see whether the iPhone 6 motherboard has broken cables, the result shows that the two chips are all normal.

3. Replace the two new chips and charge to have a test, the fault is same as before.

4. Connect the iPhone 6 with computer, It displays no data for the battery life on Ace assistant, this often happens on iPhone 6 and iPhone 6P, basically it's caused by the problem of CPU to the charge tube battery detection circuit, also the solutions are different.

5. By checking 2.2K resistance(remove R0302 and R0303 from junk motherboard) on WUXINJI schematic diagram, then connect the two resistors together. One end receives the main power supply, and the other end is grounded, and solder a jumper wire to charge tube G1 pin in the middele of the two resistors.

6. Personally, I think this method is troublesome, there is another simple way to use: add a 10K resistance (R0307 or R0310) on C1700(next to U2), which can be directly welded to one end of the C1700 PP3.0V, the other end can be welded to the charge tube G1 pin, then use green oil and UV light to solid.

7. Install the iPhone 6 device to test, charging function is normal now.

More professional cell phone repair tutorials, please visit www.vipfixphone.com

评论

此博客中的热门博文

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Solution: iPhone X Won't Turn On

According to the customer's description, the iPhone X would not turn on after it drop accidentally. Then the cell phone reports error 56 when restore it. How did this happen? Let's test and repair step by step. Since iPhone X motherboard 2 layers are connected through the middle column, the solder points are very easy to get dropped. so we guess that the solder points from NFC chip to the CPU part have fell off. Disassemble the iPhone X by iPhone opening tools , remove the upper board off the main board, when separate the main board we see there is a row of points have fell off. Check the location map on WUXINJI dongle , it is surrounded by a ground wire, in fact, there are 6 useful points dropped. The ground wire does not need to be filled, the 6 useful points are added by professional phone welding tools. These are the signal wires of the NFC chip, so the iPhone X would report error 56. Then the tin of the middle column is repaired by iPhone X BGA reballing ste...

Solution: Why iPhone X Voltage Keeps Jumping

After getting the iPhone X motherboard to test, we observe the current value repeatedly jumps between 0mA and 50mA on DC power supply , and it is different from the normal booting current. Next, test whether the power supply of every circuit is normal. PP_VDD_MAIN is measured 4.2V; PP_VDD_BOOST measured is 4.2V. PP1V8-ALWAYS is 1.8V, all the values are normal. But when testing PP1V1_S2, PP0V8_SOC_FIXED_S1, PP1V8_S2 and other circuit voltage that output by power chip U2700 voltage are jumping constantly. According to previous experience, voltage jump is usually caused by a power supply circuit of U2700 output. Measured with digital multimeter , there is no short circuit was found for the dipole value of all power supply to ground. We repaired iPhone 7P before and know that if crystal oscillator is false welding can also cause voltage jumping, And if iPhone CPU  power supply is abnormal also can cause voltage jumping. Check the crystal oscillator we find no problem, then check th...