跳至主要内容

Fixed: iPhone no fingerprint Failure


A dropped iPhone, iPhone display has been replaced, after a period of time, customer feedback that fingerprint unlock function can not be used. Check the fingerprint on the settings, prompting "failure, unable to complete the touch ID settings, please go back and try again."
 


Use Fluke 15B+ Digital Multimeter to measure the resistance value for fingerprint socket, all is normal. Replace the fingerprint connector flex cable, we found a tear mark on the iPhone fingerprint button.


Perhaps the iPhone fingerprint can't be used is caused by disconnection, we need to re-connect the new flex cable. The line inside the flex cable is very thin, total is 19 lines. This can't connect a single cable, we can only remove the flex cable to docking.

Take a new iPhone home button, put it under the Stereo Zoom Microscope, cut off from the position close to the original iPhone home button disconnection, take the end of the socket (try to cut a bit longer), we can separate the lines and lid on the original home button, there is a solder point, directly heated with the QUCIK 861DW hot air rework station, and then pry it with the blade.


After separating the iPhone home button, we can cut off the fingerprint from the disconnection place, scraping fingerprint cable must be very careful, pay attention to the direction cannot be blown back

We've better find some bad home button and then scrap the flex cable to practice, the boot flex cable can also be practiced.

After scrapingapply some tin on it, and then connect the new and old iPhone fingerprint flex cable.

After finish the connection, first we need to test it, if the test is successful, we can reinforce it. Cut off a small piece of discarded fingerprint flex cable, use glue to cover the docking area for protection. After the glue has solidified, install the iPhone and test it again. The iPhone 6 no fingerprint failure repairing done!

If you need any other professional cell phone repair information, please contact on www.vipfixphone.com

评论

此博客中的热门博文

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Iphone 6S Enters DFU Mode Cannot Start Fault Repair

The customer said that he did not know what the reason was. The mobile phone has been restarted indefinitely and can enter the DFU mode. However, when the flashing machine fails to enter the recovery mode from the DFU mode, and then the mobile phone is connected to the computer for 5-10 minutes, it automatically enters the recovery mode. After we received the 6S that could not be started, we disassembled the power with iphone engraving tool and turned on the power to 100mA. First of all, check if you can connect and read the DFU mode after connecting to the computer. Wireless DFU can not exit, we can only brush the machine to view the error. Refresh Aisi and iTunes respectively. If you stuck on the progress bar for a long time, it is very likely that the error is -1. If the progress bar does not enter, you can roughly determine the probability of a CPU failure. Now we need to see if there is a problem with the hard drive. First, use DC power supply for iphone repair, the hard disk o...

Tutorial: iPhone 6S Plus Backlight Repair

Since the size of iPhone6s plus screen display  is large, it's necessary to use two sets of background lights to supply power, one is provided by U4020, the other is provided by U4050. 2  sets of circuit 1) PP_LCM_BL_ANODE,     PP_LCM_CAT1, PP_LCM_BL_CAT2 2) PP_LCM_BL34_ANODE,  PP_LCM_BL_CAT3, PP_LCM_BL_CAT4 For PP_LCM_BL_ANODE and PP_LCM_BL34_ANODE, if one of the circuit has no voltage value, it will cause the iPhone 6s Plus screen to be half bright and half dark. For PP_LCM_CAT1, PP_LCM_BL_CAT2, PP_LCM_BL_CAT3 and PP_LCM_BL_CAT4, if one of  these four circuits gets abnormal signal, it will cause the 1/4 screen to be dark. Solution: Use jumper wire  to short connect PP_LCM_CAT1 and PP_LCM_BL_CAT2 or you can also connect PP_LCM_CAT3 and PP_LCM_BL_CAT4. The control signals of these two sets of backlights, one group of inductors FL4211 FL4212 FL4213 are sent to the display interface. The other group is sent to the display interface...