Have you ever encountered charging failure on your cell phone before? We received a iPhone 6 with the same failure. Before repairing, we need to diagnose the reason. In this article, you'll get the best solution.
The iPhone
6 was no response when charging, and there is no charge symbol displayed.
Observe the iPhone 6 motherboard under microscope, it is a perfect board, the iPhone charging flex cable is good,
and the resistance value measured by Fluke 15B+ Digital Multimeter also is no problem.
Since we didn't find the problem after
measuring, we judge the iPhone U2 IC might be damaged. Use QUICK 861DW hot air rework station to remove the
iPhone U2 IC, and then replace it with the new one.
Measure the
resistance value again after replacing the U2 IC, the data is normal. So we test the iPhone charge
function, the fault still there.
Now remove the iPhone charge tube, and then
measure the resistance value, we found the G3 pin is no resistance value.
Check iPhone schematic diagram in the WUXINJI Dongle, we know that the G3 pin is I2c 1 bus, the
G3 pin is disconnected, so the iPhone charge tube not working, no resistance
value means disconnection. We can fix it by welding the jump wire.
Closest to the iPhone charge tube is the
vibrating tube, we weld the jumper wire between them, and then install the
iPhone to test, now the problem has been solved.
Tips:
In the maintenance process, if you do not confirm the fault part, you need to change the IC, we can also measure the resistance value of the pin, so even after the replacement of IC, the problem still exists, but you can confirm that the place of replacement is no problem, so you do not need. Measure it again.
If you have an other problems, just contact us on www.vipfixphone.com
If you have an other problems, just contact us on www.vipfixphone.com