Iphone 6S Enters DFU Mode Cannot Start Fault Repair

The customer said that he did not know what the reason was. The mobile phone has been restarted indefinitely and can enter the DFU mode. However, when the flashing machine fails to enter the recovery mode from the DFU mode, and then the mobile phone is connected to the computer for 5-10 minutes, it automatically enters the recovery mode.


After we received the 6S that could not be started, we disassembled the power with iphone engraving tool and turned on the power to 100mA. First of all, check if you can connect and read the DFU mode after connecting to the computer. Wireless DFU can not exit, we can only brush the machine to view the error.


Refresh Aisi and iTunes respectively. If you stuck on the progress bar for a long time, it is very likely that the error is -1. If the progress bar does not enter, you can roughly determine the probability of a CPU failure. Now we need to see if there is a problem with the hard drive. First, use DC power supply for iphone repair, the hard disk on the left side of the capacitor can be tested to 0.9V, 1.8V, 3.0V, the result is normal power.


 

Delete the hard drive to be tested. First, it is normal to reach the resistance value. Test the hard disk using the iphone test fixture . This 6S original hard disk is damaged, the data can only be read but can only be replaced.


   

First, the serial number is queried by IMEI. Professionals with a BT WF address can find Bluetooth and WiFi addresses (called three codes). After replacing the mobile phone, the mobile phone after winning 11 must be written into the original three codes to be activated after the hard disk is replaced.


Before writing the code, first write the basic data of the corresponding model. If there is any problem with the underlying data, there will be some strange problems, which are potential errors. So you can use the JC PCIE IPhone 8 8P X NAND Test Fixture for reading and writing. After watching the camera, the screen is reversed. Rewrite the underlying data to solve the problem




There are still some hard drives on the 5.5-inch machine, 4.7-inch mobile hard drives, and incorrect underlying data may also help display normal subtitles. This 6S boot DFU brush machine does not work, we solved the problem successfully after replacing the hard disk.

评论

此博客中的热门博文

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Solution: iPhone X Won't Turn On

According to the customer's description, the iPhone X would not turn on after it drop accidentally. Then the cell phone reports error 56 when restore it. How did this happen? Let's test and repair step by step. Since iPhone X motherboard 2 layers are connected through the middle column, the solder points are very easy to get dropped. so we guess that the solder points from NFC chip to the CPU part have fell off. Disassemble the iPhone X by iPhone opening tools , remove the upper board off the main board, when separate the main board we see there is a row of points have fell off. Check the location map on WUXINJI dongle , it is surrounded by a ground wire, in fact, there are 6 useful points dropped. The ground wire does not need to be filled, the 6 useful points are added by professional phone welding tools. These are the signal wires of the NFC chip, so the iPhone X would report error 56. Then the tin of the middle column is repaired by iPhone X BGA reballing ste...

Guide: iPhone 7 Plus Camera Fault Repair

iPhone camera failure is common for most of cell phone repair technicians, today, we're going to fix iPhone 7 Plus camera. According to the holder's description, the front small camera is normal while the rear camera fails to take photos, when turn on it, the iPhone 7 shows black screen. Let's start from easy repair operation: directly replace the iPhone camera to have a test.  Note: Pay attention that two camera are connected together. When disassemble the iPhone 7P rear camera , you need to pry up from the left side.  The fault is same as before after replacing a new rear camera. We tested before, the iPhone 7P double camera is rely on the bigger camera to get image, as shown in 15-5-1, the corresponding part on iPhone 7P motherboard is J4501 pin, the resistance value is normal after testing with Fluke 15B+ digital multimeter , it reminds of us that iPhone6 Plus also encountered this phenomenon, the power supply part has some problem. By checking on  WUXINJ...