Iphone 6S Enters DFU Mode Cannot Start Fault Repair

The customer said that he did not know what the reason was. The mobile phone has been restarted indefinitely and can enter the DFU mode. However, when the flashing machine fails to enter the recovery mode from the DFU mode, and then the mobile phone is connected to the computer for 5-10 minutes, it automatically enters the recovery mode.


After we received the 6S that could not be started, we disassembled the power with iphone engraving tool and turned on the power to 100mA. First of all, check if you can connect and read the DFU mode after connecting to the computer. Wireless DFU can not exit, we can only brush the machine to view the error.


Refresh Aisi and iTunes respectively. If you stuck on the progress bar for a long time, it is very likely that the error is -1. If the progress bar does not enter, you can roughly determine the probability of a CPU failure. Now we need to see if there is a problem with the hard drive. First, use DC power supply for iphone repair, the hard disk on the left side of the capacitor can be tested to 0.9V, 1.8V, 3.0V, the result is normal power.


 

Delete the hard drive to be tested. First, it is normal to reach the resistance value. Test the hard disk using the iphone test fixture . This 6S original hard disk is damaged, the data can only be read but can only be replaced.


   

First, the serial number is queried by IMEI. Professionals with a BT WF address can find Bluetooth and WiFi addresses (called three codes). After replacing the mobile phone, the mobile phone after winning 11 must be written into the original three codes to be activated after the hard disk is replaced.


Before writing the code, first write the basic data of the corresponding model. If there is any problem with the underlying data, there will be some strange problems, which are potential errors. So you can use the JC PCIE IPhone 8 8P X NAND Test Fixture for reading and writing. After watching the camera, the screen is reversed. Rewrite the underlying data to solve the problem




There are still some hard drives on the 5.5-inch machine, 4.7-inch mobile hard drives, and incorrect underlying data may also help display normal subtitles. This 6S boot DFU brush machine does not work, we solved the problem successfully after replacing the hard disk.

评论

此博客中的热门博文

Solution: iPhone 7 Baseband Fault

Phone 6 Plus touch M1, iPhone 6 baseband u1v1 and iPhone 7 audio problems are very common for phone repairmen. At first, we can weld  iPhone touch IC  or re-install touch IC to fix iPhone 6P touch problem, but after a while it need to be repaired again. Later, we figure out that we can repair the problem by   jump wire . The baseband u1v1 and audio problems can also be used in the same way. The first layer of these iPhone motherboard layer circuit lines is very fragile and easy to disconnect or virtual welding, some are not broken by the naked eye, but in fact it is almost disconnected, weak links, at a critical point. Now, let's back to iPhone 7 baseband problem, most people think it is Qualcomm baseband problem, and we think it's still the same as before, it's iPhone motherboard design flaws.  Check the working schematic diagram of the iPhone baseband power supply through WUXINJI Dongle , it's amazing, as shown in picture 1. Put iPhone 7 and iPh

Repair Guide: iPhone 7 7P Fingerprint & Home Button Repair

If the fingerprint and home button function on iPhone 7 / 7p get failure and you don't know how to fix it, now this article will be your guide for the detailed repair process! Hope it will help!   Before repairing, open the WUXINJIDongle  to check iPhone 7/7P schematic diagram. 1. iPhone 7/7P home button repair guide The home button power supply schematic diagram is as follows: The power supply pipe U3801 output PP2V75_MAMBA(275V) to J3801, iPhone power IC  output PP1V8_TOUCH(1.8V) , through resistance R3805, final to J38011. If these two circuit power supply is abnormal, it will cause iPhone home button  failure . For repairing this problem, check short connection R3805, and then you can replace the U3801 or disassemble the U3801, and then use PPD 861D Plus   hot air rework station to weld the jump wire from C3813 to C3823. Tips: PP3V0_MESA(3.0V), PP1V8_MESA(1.8V), PP2V75_MAMBA(2.75V) and PP1V8_TOUCH(1.8V), this four circuits voltage can be teste