iPhone 6 No Sound Repair: Microphone Earphone Speakers

Sound fault is the most common in cell phone repairs, there are many chips control the sound function, so you need to be careful to avoid more malfunction during repairs. This iPhone 6 has ringtone sound when receiving calls, but the speaker icon turns grey after connection. As shown in picture 12-5-1.
 



First, we use the simplest elimination method to diagnose where the fault comes from, removing the iPhone 6 charging flex cable  to check the receiver; removing the earphone to test the speaker. After testing, there is still no voice. It can be judged that the chip is out of order.

The iPhone 6 U0900 big audio damage directly caused the 3 voice failure, it's relatively simple to disassemble and assemble large audio chip, layer welding spot is large while the iPhone audio chip is big and thin, so it's necessary to avoid excessive force to crush the chip during solder reballing process. Replace U0900 chip, all sound tests OK. U0900 position is shown in picture 12-5-2.

U1601 small audio water damaged phone comes out of a lot of problems, leading to large current, and there will be an automatic phone speaker. If the reset signal given by the iPhone CPU is abnormal, we can scrape and weld a jumper wire from the bottom of the chassis A6 track.

If the sound off and on, you can remove a small audio chip, when there is a temperature, measure the resistance value of the U1601 A6 track by digital multimeter.


iPhone 6 will also have a headphone mode, which automatically enters the headset mode without the plug in the headset.

The J1817 tail plug can be tested. If the block is normal, it will be solved by replacing the tail plug flex cable.

If there is the absence of a single sound instead of 3, we can replace the new components, detect the circuit, test the block value, and basically can find the problem.

More mobile phone fix solutions read on www.vipfixphone.com


评论

此博客中的热门博文

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Solution: Why iPhone X Voltage Keeps Jumping

After getting the iPhone X motherboard to test, we observe the current value repeatedly jumps between 0mA and 50mA on DC power supply , and it is different from the normal booting current. Next, test whether the power supply of every circuit is normal. PP_VDD_MAIN is measured 4.2V; PP_VDD_BOOST measured is 4.2V. PP1V8-ALWAYS is 1.8V, all the values are normal. But when testing PP1V1_S2, PP0V8_SOC_FIXED_S1, PP1V8_S2 and other circuit voltage that output by power chip U2700 voltage are jumping constantly. According to previous experience, voltage jump is usually caused by a power supply circuit of U2700 output. Measured with digital multimeter , there is no short circuit was found for the dipole value of all power supply to ground. We repaired iPhone 7P before and know that if crystal oscillator is false welding can also cause voltage jumping, And if iPhone CPU  power supply is abnormal also can cause voltage jumping. Check the crystal oscillator we find no problem, then check th...

Iphone 6S Enters DFU Mode Cannot Start Fault Repair

The customer said that he did not know what the reason was. The mobile phone has been restarted indefinitely and can enter the DFU mode. However, when the flashing machine fails to enter the recovery mode from the DFU mode, and then the mobile phone is connected to the computer for 5-10 minutes, it automatically enters the recovery mode. After we received the 6S that could not be started, we disassembled the power with iphone engraving tool and turned on the power to 100mA. First of all, check if you can connect and read the DFU mode after connecting to the computer. Wireless DFU can not exit, we can only brush the machine to view the error. Refresh Aisi and iTunes respectively. If you stuck on the progress bar for a long time, it is very likely that the error is -1. If the progress bar does not enter, you can roughly determine the probability of a CPU failure. Now we need to see if there is a problem with the hard drive. First, use DC power supply for iphone repair, the hard disk o...