Solution: iPhone 6 Touch Failure

The touch function of the iPhone 6 is not working properly now. According to the last repairman's description, the device has been sent to fix by many phone repair shops but they still didn't fix it. He wants to see if we can fix it with professional phone repair tools.

After we received the iPhone, we tested it and found that the fault was a little different. The specific failure performance is that the iPhone shows normal after entering the IOS, touch it with your fingertips has no effect; Touch it with your finger on the iPhone display screen, it works but not sensitive; If a little bit of force is used to press the screen to slide, it can be used normally. However, it's obvious that the owner of iPhone can't use the phone properly.

Testing it by disassemble the iPhone, we found the white touch IC and black touch IC has been replaced. Because the phone has been repaired many times, although not repaired, but these two chips have been replaced, which means that they are normal. And then we according to the fingers with a little force can slide to judge the line that from black touch IC to touch socket and touch socket itself are good. Because if they are abnormal, either the display screen will appear with a vertical bar or the touch is completely unavailable. Either lack of transverse or lack of vertical, but in the actual test did not find a lack of transverse or lack of vertical phenomenon, so the above judgments is correct.

And then according the above phenomenon, we judged the circuit line that from iPhone CPU to white touch IC also normal, so we decided to repair it starting from these two chips peripheral circuits. Use Fluke 15B+ Digital Multimeter to measure the black touch IC +-5.7V voltage and 1.8V voltage, all is normal. Measuring the white touch IC 5.1V and 1.8V, also is normal. Then we think it would be more precise to use the Hantek DSO1060 oscilloscope to measure, but the result of the oscilloscope measurement is normal. There is no idea now, we open the WUXINJI circuit diagram and analyze it, see if we can find out the reason and solution.

After checking the WUXINJIcircuit diagram, seems find nothing. But we see a bias capacitor C2439 on the black touch circuit, and then think of the iPhone that was repaired, which the audio have sound, but the sound is small or very light fault, all of these failures are repaired by replacing the audio bias capacitor next to the iPhone audio IC. Will this touch faulty be caused by this bias capacitor?


Measure the diode data of other ungrounded ends first, we found that it's about the same as the normal board, but we still decided replace it with new one. Then we remove a same capacitor from damaged motherboard, and install it with QUICK 861DW soldering station. The result is that the fault is perfectly repaired.

More cell phone repair tutorials please visit at www.vipfixphone.com

评论

此博客中的热门博文

iPhone 6 Display Failure after Replacing LCD

The iPhone 6 display is black after replacing LCD. After checking, the diode data of display socket is normal and all power supply for iPhone display IC  output is normal. Testing by  DC power supply , we find the iPhone current is abnormal. When press the iPhone power button, the boot current is obviously large. The current reached 100mA when press the power button. After remove the display tube, the current still the same, which means there is a short circuit. Measure the voltage output of each circuit of power supply with Fluke 15B+ Digital Multimeter , then surprised to find that there are really short circuit places. LD010 is short circuit; we suspect that the filter capacitance on the circuit has been penetrated. After remove the iPhone power control IC , we found it is ground short circuit. Open the WUXINJI Dongle  to check the iPhone schematic circuit, we found that this circuit is the display card image transmission MIPI data bus power supply. CPU brea...

Solution: Why iPhone X Voltage Keeps Jumping

After getting the iPhone X motherboard to test, we observe the current value repeatedly jumps between 0mA and 50mA on DC power supply , and it is different from the normal booting current. Next, test whether the power supply of every circuit is normal. PP_VDD_MAIN is measured 4.2V; PP_VDD_BOOST measured is 4.2V. PP1V8-ALWAYS is 1.8V, all the values are normal. But when testing PP1V1_S2, PP0V8_SOC_FIXED_S1, PP1V8_S2 and other circuit voltage that output by power chip U2700 voltage are jumping constantly. According to previous experience, voltage jump is usually caused by a power supply circuit of U2700 output. Measured with digital multimeter , there is no short circuit was found for the dipole value of all power supply to ground. We repaired iPhone 7P before and know that if crystal oscillator is false welding can also cause voltage jumping, And if iPhone CPU  power supply is abnormal also can cause voltage jumping. Check the crystal oscillator we find no problem, then check th...

Guide: iPhone 7 Plus Camera Fault Repair

iPhone camera failure is common for most of cell phone repair technicians, today, we're going to fix iPhone 7 Plus camera. According to the holder's description, the front small camera is normal while the rear camera fails to take photos, when turn on it, the iPhone 7 shows black screen. Let's start from easy repair operation: directly replace the iPhone camera to have a test.  Note: Pay attention that two camera are connected together. When disassemble the iPhone 7P rear camera , you need to pry up from the left side.  The fault is same as before after replacing a new rear camera. We tested before, the iPhone 7P double camera is rely on the bigger camera to get image, as shown in 15-5-1, the corresponding part on iPhone 7P motherboard is J4501 pin, the resistance value is normal after testing with Fluke 15B+ digital multimeter , it reminds of us that iPhone6 Plus also encountered this phenomenon, the power supply part has some problem. By checking on  WUXINJ...